General Module Function
The extract cell comp module extracts a single cell based data component from a field containing cell based data. Extract cell component can extract cell based scalar data components or vector components. Scalar components will be output as scalar components and vector components will be output as vector components, one component for each cell.
Module Input Ports
Extract cell comp has only one input port which accepts any mesh type with cell based data.
Module Output Ports
Extract cell comp has two output ports. The first port (closest to the left) contains a reference to a merged object that contains the new cell based data, plus references to all other unchanged objects in the input Mesh. The second port is undocumented at this time.
Module Control Panel
The control panel for extract cell component is shown in the figure above. The data component radio button list contains all of the cell data components piped into the input port. Only one component can be selected at a time and the default selection is the first (0th) data component. Any modules downstream of extract cell component will only receive the selected data component.
Related Modules